Driver Booster 4, as a powerful and easy-to-use driver updater, provides 1-click solution to rapidly & securely update outdated and faulty drivers and install the best matched missing drivers not only for your device drivers but also for. Software Downloads. A list of Clipsal Integrated Systems current software products is shown below, click the name of the product you want to download. The software is packaged in a ZIP file. To unzip the file and access the software you will need to use an application that supports zip files, for example WinZip. If you are using Windows XP.

Specifications

64-bit
Input Voltage[+VDC] nominal 24 /48
[+VDC] min/max12/60
Supply current[A] max per unit3.5
Aux supply[+VDC]12 / 24
Aux current[mA] max per unit200
Temperature[C°] heat sink85
[C°] motor100
IP rating IP20

Connecting the Power Supply

Port

Read the Product Hardware Manual Section 5: Engineering before connecting DC Power.

  • Use shielded twisted pairs for cabling with shield earthed at the power supply end.
  • Power supply wiring should be shielded twisted pairs. Use 18 AWG wires if load is less than 4 amps, or 16 AWG for more than 4 amps.
  • Never use a “daisy-chain” power supply wiring scheme to system components.
Pin 1Power supply output voltage
Pin 2Power supply return (Ground)

Connecting communication

SEM recommends using the MD-CC404-000 USB to RS-422/485 communication converter with first Lexium MDrive purchase. This Plug and play adapter and cable kit needs only be connected from your PC to the DB9M connector at P3.

If using a third-party RS-422 / 485 converter or PC card P3 is pinned as follows (Pins not listed are not connected):

Pin 2TRANSMIT -Pin 6COMM_GND
Pin 3RECEIVE +Pin 7TRANSMIT +
Pin 4COMM_GNDPin 8RECEIVE -

MD-CC404-000 USB to RS485 Converter

If using the MD-CC404-000 ensure an Internet connection to the PC is present, drivers should automatically install. If using an operating system other than Microsoft Windows®, or drivers fail to install on plug-in, they may be downloaded fromthis page: https://www.ftdichip.com/Drivers/VCP.htm

Lexium MDrive Ethernet uses an RJ45 connector with standard Ethernet wiring, standard off-the-shelf RJ45 and CAT 5 cabling may be used with no special wiring considerations beyond those defined in IEEE 802.3.
Lexium MDrive Profinet uses an RJ45 connector with standard Ethernet wiring, standard off-the-shelf RJ45 and CAT 5 cabling may be used with no special wiring considerations beyond those defined in IEEE 802.3.
Lexium MDrive Ethernet with M12 circular connectors uses the ODVA standard 4-position M12 female D-coded connector with standard Ethernet cabling with no special wiring considerations beyond those defined in IEEE 802.3. For ease of prototyping a 6'6' (2.0 m) RJ45 to M12 (M, D-coded) cable, the MD-CS640-000, is available.

SEM recommends using the MD-CC501-000 USB to CANopen communication converter with first Lexium MDrive purchase. This adapter and cable kit with terminating resistor block needs only be connected from your PC to the DB9M connector at P3 following driver installation. Note that the MD-CC501-000 or equivalent PEAK/PHYTEC adapter is REQUIRED to field upgrade firmware or use the CANopen Configuration Utility.

Any CANopen controller or adapter may be used to configure the device via LSS (Layer Setting Services), Cabling and connector pinning follows CiA DR-303-1

Pin 2CAN_LPin 6GND
Pin 3CAN_GNDPin 7CAN_H
Pin 5CAN_SHLDPin 9CAN_V+

The drivers and installation guide for this adapter kit may be found on the included DVD. Alternately, they may be downloaded from https://www.peak-system.com/PCAN-USB.199.0.html?&L=1

SEM recommends using the MD-CC502-000 USB to CANopen communication converter with first Lexium MDrive purchase. This adapter and cable kit with terminating resistor block needs only be connected from your PC to the M12 (Male) A-coded connector at P3 following driver installation. Note that the MD-CC502-000 or equivalent PEAK/PHYTEC adapter is REQUIRED to field upgrade firmware or use the CANopen Configuration Utility.

Any CANopen controller or adapter may be used to configure the device via LSS (Layer Setting Services), cabling and connector pinning follows CiA DR-303-1

Schneider electric port devices driver download for windows 10 windows 7

Schneider Electric Port Devices Driver Download For Windows 10 64-bit

If multiple units need to be daisy chained together, a Y-splitter, the MD-CS660-000, is available.

Schneider Electric Port Devices Driver Download For Windows 10 Windows 7

Pin 1CAN_SHLDPin 4CAN_H
Pin 2CAN_V+Pin 5CAN_L
Pin 3CAN_GND

Schneider Electric Port Devices Driver Download For Windows 10 Xp